電話: +86-19056415571 Eメール: Mike@tanjie.com.cn

に関しては 接触 |

X510 floor scrubber clean work in hospital - タンジークリーン

X510 floor scrubber clean work in hospital

X510 floor scrubber in a hospital is a critical task that requires a blend of technical skill, strict adherence to infection control protocols, and awareness of the sensitive environment.

Here is a comprehensive, step-by-step guide for cleaning work with an X510 床スクラバー in a hospital setting.

https://www.tanjieclean.com/product-category/hand-pushed-floor-scrubber/


Guiding Principle: Infection Control First

In a hospital, the primary goal is not just to clean for appearance, but to disinfect to prevent the spread of Healthcare-Associated Infections (HAIs). The floor scrubber is a tool to apply disinfectant solution and physically remove soil and microbes.


Phase 1: Pre-Cleaning Preparation & Safety

1. Personal Protective Equipment (PPE):

  • Mandatory: Disposable gloves, safety glasses, and slip-resistant shoes.

  • As Required: A fluid-resistant gown or apron and a face mask, especially when cleaning isolation rooms or areas with a high risk of splash.

2. Prepare the Area:

  • Post Signs: PlaceWet Floor” 又は “Cleaning in Progresssigns at all entrances to the area to prevent slips and falls.

  • Clear the Path: Remove small, movable obstacles like trash cans, chairs, and equipment cords. Work around large, fixed objects.

  • Check for Hazards: Look for spills, sharp objects, or other hazards that could damage the machine or cause injury.

3. Machine Pre-Operation Check:

  • Inspect the Machine: Check the X510 for any visible damage, loose parts, or leaks.

  • 電池 & Charger: Ensure the battery is fully charged. Connect the charger correctly (always plug the charger into the wall before connecting to the machine to prevent arcing).

  • Check Pads/Brushes & Squeegee:

    • Inspect the scrub deck pad or brush for wear and ensure it’s properly installed.

    • Check the rear squeegee for cracks or damage and ensure it is clean and correctly positioned.

  • Solution and Recovery Tanks:

    • Empty the Recovery Tank: Start with an empty and clean recovery tank. A full tank will severely hamper performance.

    • Prepare the Solution Tank: Fill with clean water and the hospital-approved disinfectant detergent. CRITICAL: Follow the manufacturer’s dilution instructions precisely. Under-dosing is ineffective; over-dosing can leave a sticky residue and damage the machine.